When designing and constructing external wall systems, the question often arises: Is a breather membrane always necessary?

nnn

Applying a breather membrane over sheathing boards installed on Steel Framing Systems (SFS) is strongly recommended for several reasons. This is evidenced by information from authoritative sources in the construction industry, some of which are set out below.

n
nnn
n
nnn
n
nnn
n
Breather Technical Detail Visual edited scaled
n
nnn
n
nnn

The Purpose and Function of a Breather Membrane

nnn

Breather Membranes provide an extra layer of weather resistance and are included within external-wall structures to increase the resistance to water ingress.  Their inclusion or otherwise should not be dependent on the type of sheathing board being used.

nnn

Although most sheathing boards offer a measure of durability and water resistance, they are rigid panels with joints and fixings. Cement/calcium silicate boards resist water ingress, but moisture may eventually pass through if the board is subject to soaking. Gypsum boards have a glasmat top layer which, if penetrated, even with redundant screw holes or from mishandling or damage from other trades, can lose all structural integrity if it gets damp.

nnn

On the other hand, a Breather Membrane can be easily dressed, wrapped, and sealed (typically with tapes) around interfaces and penetrations, providing the structure with a much greater level of resistance to water ingress.

nnn

Even though the sheathing board may possess BBA certification, it does not eliminate the requirement for a Breather Membrane.  A Breather Membrane uniquely acts as a barrier, preventing water from seeping inward through the wall whilst still allowing water vapour to diffuse outward, making it an essential element in fa√ßade through-wall systems.

nnn

Longevity and Durability
The concern is that without a breather membrane, excessive water and moisture will enter the external wall during construction and be unable to escape or evaporate once the fa√ßade is in place. This can lead to severe deterioration of the sheathing board, SFS and insulation. This moisture in the external wall can also cause dampness and mould internally, creating irreversible damage to the building. 

nnn

Performance Standards
Breather Membranes, when tested, are required to achieve high levels of water resistance, such as a minimum W2 to BS EN 13859-2.

nnn

The Breather Membrane should satisfy several key criteria:

nnn
    n
  • It should carry suitable third-party accreditation for use as a breather membrane.
  • nnn
  • Its vapour resistance should be less than 0.6MNs/g when tested in accordance with EN ISO 12572 set C and five specimens. 
  • nnn
  • The membrane should possess a minimum B-s1,d0 fire-classification according to EN 13501-1
  • nnn
  • It should be rated at least Class W2 to BS EN 13859-2.  In areas of extreme exposure or anticipated liquid water penetration of the facade, Class W1 should be used.
  • n
nnn

Environmental Benefits
Breather Membranes can contribute to a longer building lifespan, resulting in a lower embodied carbon footprint. The spread of embodied carbon over a more extended period reduces average annual emissions, making the buildings more sustainable and environmentally friendly in the long run. Breather membranes also contribute to airtightness, which improves the efficiency of the building.

nnn

Positioning and Functionality
The correct positioning of the breather membrane is crucial. It can be located either on the outer face of insulation within the cavity or on the outside face of the sheathing board.

nnn

Thermal Efficiency and Temporary Protection
Most W1 Breathable Membranes are also air-tight, improving the thermal efficiency of a building’s external envelope and providing temporary protection from the weather during construction or repair works. This dual function enhances both the building’s energy performance and its resilience during the construction phase.

nnn

Water Resistance and Vapour Permeability
Breather Membranes are water-repellent yet vapour-permeable, also known as microporous.  As a rule of thumb, they are recommended to be 20 times more vapour permeable than the internal vapour control layer (VCL). These membranes prevent any moisture, snow, wind and contaminants that may penetrate through the cladding from further entering the structure, whilst their vapour permeability prevents the buildup of interstitial condensation.

nnn

Summary

nnn

In summary, installing Breather Membranes over sheathing boards is considered critical for superior performance in water resistance, durability, and environmental sustainability, as well as for achieving regulatory compliance with all applicable technical and performance standards. This ultimately ensures the long-term integrity and functionality of the building structure.

nnn

It is also to be noted that introducing a breather membrane does not remove the necessity for an Interface Sealing Membrane around the perimeter of the SFS panel at slab edge and column interfaces.

nnn

References:
Understanding why breathable membranes are required in external walls (pbctoday.co.uk)

nnn

Breather membranes on framed structures (pbctoday.co.uk)

nnn

Breather membranes for buildings – Designing Buildings

nnn
n
nnn
n

References:

nnn

CWCT  –  Technical Note No. 33

nnn

NHBC  –  Section 6.10.14

nnn

LABC Warranty  –  Section 6.3.4