This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
EI60 Through Wall System
The OBEX Through-Wall Systems have been fully tested to different EI ratings in several variations, and with different third-party materials including the insulation and SFS system. These are detailed below under the different test numbers.
If a different third-party material is required other than those mentioned below, please contact us to organise a full complimentary system test.
Certified Fire Rating: EI60
Test Orientation: Test 1 – Inside to Outside Test 2 – Inside to Outside
OBEX Products
- VCL: Test 1 & 2 – OBEX CORTEX 0230FR Vapour Control Layer – Class A2
- Sheathing Board: Test 1 & 2 – OBEX CORTEX 0270FR Score’N’Snap Cement Board – Class A1
- Breather: Test 1 – OBEX CORTEX 0223FR Breather Membrane – Class A2. Test 2 – OBEX CORTEX 0221FR Breather Membrane
Third-Party Products
- SFS: Test 1: Metsec Test 2: EOS
- Plasterboard: Test 1 – 2 Layers 12.5mm BG Standard Board. Test 2 – 2 Layers of 12.5mm Siniat Fire Board
- Internal Insulation: Test 1 – 75mm Rockwool. Test 2 – 75mm RWA45
- External Insulation: Test 1 – Not Included. Test 2 – 75mm Rockwool Duoslab
- 3rd Party Certified
- EI60 Fire Test Component